Close
Lakatamia, 2303 Nicosia Aigaiou 29
Monday - Friday 7AM - 5PM

VALENTINES SOLAR uses copper for all boilers (water cylinders) as copper is known for its longevity (+20 years of lifetime). High density polyurethane is used for the insulation of the boilers giving the perk that the water stored is not affected by the outside atmosphere/temperature. All boilers include an electrical water heating element – 3KW.

In addition with our highly skilled labour and modern machinery we are able to produce water cylinders with customized inputs and outputs for the best “fitting” and needs of each customer.

Depending on the type of system there are different types of boilers.
e.g
1) Low pressure (1bar)
2) High Pressure (9bar)
3) Close loop (9bar)

LOW PRESSURE HOT WATER BOILERS (Horizontal)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
V100LT 92 86 44 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V150LT 149 98 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V200LT 195 118 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V250LT 247 155 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V300LT 305 180 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V350LT 355 205 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1

HIGH PRESSURE HOT WATER BOILERS (Horizontal)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
VP100LT 92 86 44 Copper 1.5 mm X 2 mm Polyurethane 3KW 9
VP150LT 149 98 58 Copper 1.5 mm X 2 mm Polyurethane 3KW 9
VP200LT 195 118 58 Copper 1.7 mm X 2 mm Polyurethane 3KW 9
VP250LT 247 155 58 Copper 1.8 mm X 2 mm Polyurethane 3KW 9
VP300LT 305 180 58 Copper 1.8 mm X 2 mm Polyurethane 3KW 9
VP350LT 355 205 58 Copper 1.8 mm X 2 mm Polyurethane 3KW 9

LOW PRESSURE HOT WATER BOILERS (Vertical)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
V100LT 92 86 44 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V150LT 149 98 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V200LT 195 118 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V250LT 247 155 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V300LT 305 180 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
V350LT 355 205 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1

HIGH PRESSURE HOT WATER BOILERS (Horizontal)

ModelCapacity (L) +/-2.5%Length (CM)Diameter (CM)Storage Tank MaterialTank Material ThicknessInsulation MaterialElectrical Resistance (KW)Testing Pressure (BAR)
VP100LT 92 86 44 Copper 1.5 mm X 2 mm Polyurethane 3KW 9
VP150LT 149 98 58 Copper 1.5 mm X 2 mm Polyurethane 3KW 9
VP200LT 195 118 58 Copper 1.7 mm X 2 mm Polyurethane 3KW 9
VP250LT 247 155 58 Copper 1.8 mm X 2 mm Polyurethane 4KW 9
VP300LT 305 180 58 Copper 1.8 mm X 2 mm Polyurethane 4KW 9
VP350LT 355 205 58 Copper 1.8 mm X 2 mm Polyurethane 4KW 9

ELECTRIC LOW PRESSURE BOILER (Horizontal)

ModelCapacity (L) +/-2.5%Length (CM)Diameter (CM)Storage Tank MaterialTank Material ThicknessInsulation MaterialElectrical Resistance (KW)Testing Pressure (BAR)
VEP50LT 50 50 45 Copper 0.65 mm X 0.85 mm Polyurethane 3KW 1
VEP100LT 90 90 44 Copper 0.65 mm X 0.85 mm Polyurethane 3KW 1

MACHINERY BOILER HIGH PRESSURE (Vertical)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
VPM100LT 92 86 44 Copper 1.5mm x 2mm Polyurethane 3KW 9
VPM150LT 149 98 58 Copper 1.5mm x 2mm Polyurethane 3KW 9
VPM200LT 195 118 58 Copper 1.7mm x 2mm Polyurethane 3KW 9
VPM250LT 247 155 58 Copper 1.8mm x 2mm Polyurethane 4KW 9
VPM300LT 305 180 58 Copper 1.8mm x 2mm Polyurethane 4KW 9
VPM350LT 355 205 58 Copper 1.8mm x 2mm Polyurethane 4KW 9