VALENTINES SOLAR uses copper for all boilers (water cylinders) as copper is known for its longevity (+20 years of lifetime). High density polyurethane is used for the insulation of the boilers giving the perk that the water stored is not affected by the outside atmosphere/temperature. All boilers include an electrical water heating element – 3KW.

In addition with our highly skilled labour and modern machinery we are able to produce water cylinders with customized inputs and outputs for the best “fitting” and needs of each customer.

Depending on the type of system there are different types of boilers.
e.g
1) Low pressure (1bar)
2) High Pressure (9bar)
3) Close loop (9bar)

LOW PRESSURE HOT WATER BOILERS (Horizontal)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
HNS100 92 90 44 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
HNS150 149 95 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
HNS200 195 114 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
HNS250 247 154 58 Copper 0.65mm x 0.85mm Polyurethane 4KW 1
HNS300 305 185 58 Copper 0.65mm x 0.85mm Polyurethane 4KW 1

HIGH PRESSURE HOT WATER BOILERS (Horizontal)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
HPS100 92 90 44 Copper 1.6 mm X 2 mm Polyurethane 3KW 10
HPS150 149 100 58 Copper 1.6 mm X 2 mm Polyurethane 3KW 10
HPS200 195 122 58 Copper 1.6 mm X 2 mm Polyurethane 3KW 10
HPS250 247 154 58 Copper 2 mm X 2 mm Polyurethane 4KW 10
HPS300 305 185 58 Copper 2 mm X 2 mm Polyurethane 4KW 10

LOW PRESSURE HOT WATER BOILERS (Vertical)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
VNS100 92 90 44 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
VNS150 149 96 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
VNS200 195 114 58 Copper 0.65mm x 0.85mm Polyurethane 3KW 1
VNS250 247 154 58 Copper 0.65mm x 0.85mm Polyurethane 4KW 1
VNS300 305 185 58 Copper 0.65mm x 0.85mm Polyurethane 4KW 1

HIGH PRESSURE HOT WATER BOILERS (Horizontal)

ModelCapacity (L) +/-2.5%Length (CM)Diameter (CM)Storage Tank MaterialTank Material ThicknessInsulation MaterialElectrical Resistance (KW)Testing Pressure (BAR)
VPS100 92 90 44 Copper 1.6 mm X 2 mm Polyurethane 3KW 10
VPS150 149 100 58 Copper 1.6 mm X 2 mm Polyurethane 3KW 10
VPS200 195 122 58 Copper 1.6 mm X 2 mm Polyurethane 3KW 10
VPS250 247 154 58 Copper 2 mm X 2 mm Polyurethane 4KW 10
VPS300 305 185 58 Copper 2 mm X 2 mm Polyurethane 4KW 10

MACHINERY/ INDUSTRIAL HOT WATER BOILERS

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
MP2C150 144 100 58 Copper 1.5mm x 2mm Polyurethane 3KW 9
MP2C200 178.5 122 58 Copper 1.7mm x 2mm Polyurethane 3KW 9
MP2C250 232 154 58 Copper 1.8mm x 2mm Polyurethane 4KW 9
MP2C300 286 185 58 Copper 1.8mm x 2mm Polyurethane 4KW 9

JACKET PRESSURE HOT WATER BOILERS WORKING WITH GLYCOL (ANTIFREEZE)

Model Capacity (L) +/-2.5% Length (CM) Diameter (CM) Storage Tank Material Tank Material Thickness Insulation Material Electrical Resistance (KW) Testing Pressure (BAR)
JPS150 144 100 58 Copper 1.5mm x 2mm Polyurethane 3KW 9
JPS200 178.5 122 58 Copper 1.7mm x 2mm Polyurethane 3KW 9
JPS250 232 154 58 Copper 1.8mm x 2mm Polyurethane 4KW 9
JPS300 286 185 58 Copper 1.8mm x 2mm Polyurethane 4KW 9